"A Winner of Elcina Award & Excellence in Electronics" from Govt. of India      Website Updated on 08 Nov 2008
 
 

SUPCON CHINA OFFICE

  • ISO 9001 : 2000, CE.
  • 1600 Employees, 10,000 Sq m area.
  • 3 Factories, 22 Offices.
  • DCS-National famous brand award.
  • Approvals - Monsado, AKCC, SINOPEE (China), GMCC.
  • DCS sales (2006) - 91 million US$.
...............................................................................................................................................................................
DISTRIBUTED CONTROL SYSTEM

  • 2000 Sets installed.
  • Hot pluggable module.
  • Communication control network Sc net II.
  • 15-control station, 32 operating station Sbus for I/O communication.
  • 15,360 I/O.
  • 1:1 hot backup of master controller module.
  • SOE (sequence of event recorder).
  • Redundant configuration.
JX300XP
...............................................................................................................................................................................
DISTRIBUTED CONTROL SYSTEM

  • 31 redundant control station.
  • 64 operating station.
  • 20,000 I/O.
  • 1 control station (192 loops-50ms cycle time).
  • Advan Trol Pro s/w.
ECS100X
...............................................................................................................................................................................
CHARTLESS RECORDER

  • Display : 5.6" TFT (CCFL) color.
  • Input: 12AI channels, universal input.
  • Output: 12 relays.
  • Communications : RS-232/RS-485/Ethernet.
  • Accuracy : ±0.1%.
  • 8MB bytes flash memory.
R 3000

...............................................................................................................................................................................
CHARTLESS RECORDER

  • Display : 10.4" TFT (CCFL) color.
  • Input: 32 AI channel, universal input.
  • Output: 32 relays.
  • Communications : RS-232/RS-485/ Ethernet.
  • Accuracy : ±0.1%.
  • 32MB (up to 72MB) flash memory.
R 5000

...............................................................................................................................................................................
ZENER BARIER

  • Atmospheric pressure : 80~110 Kpa.
  • Explosion-proof standard : Ex (ia) II C Ex (ia) II B.
  • Triple redundancy circuit.

 



   
...............................................................................................................................................................................
ISOLATOR

  • Single/Dual channel.
  • Input: RTD,T/C,mA,V.
  • Output: mA,V, Relay.
  • Sleek design.

...............................................................................................................................................................................
SUPCON CALIBRATOR

  • Measure / Source: V, mA, RTD, T/C, frequency, Ohms.
  • 51/4 digits display.
  • Accuracy: 0.02%, CE marked.


 
...............................................................................................................................................................................