Universal Scanner 32 channel - vertical mode |
96(W) x 192(H) x 200(D) mm |
- Input : RTD T/C. mA DC & DC Volt
- Alarm/Trip relay output & trip type configurable
- Output : 4-20 mA DC (opt.)
- RS485/RS232 communication (MODBUS) (Opt.)
- Accuracy : 0.25% of span, ± 1 digit
- Supply : 90-270V AC
|
|
|
Catalogue |
|
| |
 |
Digital Scanner (8 Channel) |
96(H)x192(W)x178(D)mm |
- Input : RTD, T/c, mADC & DC Volt.
- Alarm/Trip relay output & trip type configurable.
- Output : 4-20 mADC corresponding to channel having maximum temp. for RTD & T/c input (Opt.)
|
µSCAN |
|
Catalogue |
|
|
............................................................................................................................................................................... |
 |
Digital Scanner (16 Channel) |
|
144(H)x144(W)x325(D)mm |
- Input : RTD, T/c, mADC & DC Volt.
- Alarm/Trip relay output & trip type configurable.
- Output : 4-20 mADC (Opt.).
- RS 485/RS 232 Communication (MODBUS).
|
µSCAN-16 |
|
Catalogue |
|
|
|
............................................................................................................................................................................... |
 |
Digital Scanner (32 Channel) |
|
144(H)x288(W)x187(D)mm |
- Input : RTD, T/c, mADC & DC Volt.
- Alarm/Trip relay output & trip type configurable.
- Output : 4-20 mADC (Opt.).
- RS 485/RS 232 Communication (MODBUS).
|
µSCAN-32 |
|
Catalogue |
|
|
............................................................................................................................................................................... |
 |
Universal Scanner (12 Channel) |
|
96(H)x96(W)x166(D)mm |
- Input : Universal.
- Upto 2 groups configurable for any combination of channel with 2 relay per group.
- Common dead band, auto scan, hold mode, skip facilities.
- Scan time : 2 to 12 sec.
- Supply : 110/230V AC.
|
70S-96 |
|
DataSheet |
|
|
............................................................................................................................................................................... |
 |
Universal Scanner (16 Channel) |
144(H)x144(W)x166(D)mm |
- Input : Universal.
- Programmable alarm & trip set points for each channel.
- Output : 6 nos. relays.
- Grouping of relays programmable.
- Common dead band, auto scan, hold mode, skip facility.
- Scan time : 2 to 12 sec.
- Supply : 90-270V AC.
|
µSCAN-16U |
|
DataSheet |
|
| ............................................................................................................................................................................. |
|
 |
Universal Scanner (32 Channel) |
144(H)x288(W)x50(D)mm |
- Input : Universal.
- Programmable alarm & trip set points for each channel.
- Output : 8 nos. relays.
- Grouping of relays programmable.
- Common dead band, auto scan, hold mode, skip facility.
- Scan time : 2 to 12 sec.
- Supply : 90-270V AC.
|
µSCAN-32U |
|
DataSheet |
|
|
| ............................................................................................................................................................................... |
 |
Digital Scanner (16 Channel) |
192(H)x96(W)x280(D)mm |
- Input : RTD, T/c, mADC.
- Alarm/trip relay output & trip type configurable.
- Output : 4-20 mADC corresponding to channel having maximum temp. for RTD & T/C input (Opt.).
- Password Facility.
|
|
|
Catalogue |
|
| .............................................................................................................................................................................. |
 |
Digital Scanner (16 Channel) |
266(H)x186(W)x96(D)mm |
- Input : RTD, T/c, mADC.
- Alarm/trip relay output & trip type configurable.
- Mounting: Field (IP-65)
|
µSCAN-16F |
|
Catalogue |
|
............................................................................................................................................................................... |
 |
Digital Scanner (32Channel) |
144(H)x288(W)x50(D)mm |
- Input : RTD, T/c, mADC.& DCvolt.
- Programmable alarm & trip set Points for each channel.
- Output : 8 nos relays
- Groping of Relays Programmable.
- Scantime:2 to 12sec.
|
|
|
DataSheet |
|
|
............................................................................................................................................................................... |
 |
2 Wire Temp - Max Transmitter |
|
146(H)x222(W)x55(D) mm |
- No. of channels : 2, 4, 6.
- Output : 4-20 mADC.
- Display : 7 segment LCD, 3½ sigit.
- Supply : 13-36V DC.
|
TM-2000 |
|
Catalogue |
|
|
............................................................................................................................................................................... |
 |
4 Wire Temp - Max Transmitter |
|
232(H)x304(W)x99(D) mm |
- No. of channels : 2, 4, 6.
- Output : 0-20 mA/4-20 mADC.
- Display : 7 segment LED, 3½ digit.
- Different push buttons for different channels.
|
|
|
|
|
|
............................................................................................................................................................................... |
 |
4 Wire Temp - Max Transmitter |
|
232(H)x304(W)x99(D)mm |
- No. of channels : 2+1(spare), 4+1, 6+1.
- Output : 0-20 mA/4-20 mADC.
- Display : 7 segment LED, 3½ digit.
- Single push button for different channels.
|
TM-4000 |
|
Catalogue |
|
|
| .......................................................................................................................................................................... |
 |
Scanner with modbus connectivity |
| |
| |
|
|
|
............................................................................................................................................................................... |