Multi Functional Transducer (MFT) |
13.8(L)x70.3(W)x147.5(H)mm |
- Input : Voltage Max. 600 V (P-P) – Input current (0-1/0-5 Amp)
- Output : RS 485/RS 232 communication (MODBUS protocol); 4 Analog outputs.(Opt).
- Supply : 80-260 VAC/80-330 VDC 48 VDC
- Accuracy : ±0.25% for Power Parameters.
- Load Resistance : 500?
- Isolation : Galvanic & optical
|
MFPT-101 |
|
Catalogue |
|
| |
 |
Transducer(Field/Back of panel) |
- Input : Ac Amp., AC volts, Frequency, Resistance, watt.
- Output : 4-20 mADC Linear.
- Supply : 230/110 VAC.
- Accuracy : ± 0.2% of span.
- Load resistance : 0-750 ohms.
- Optical and galvanic isolation.
|
|
|
Catalogue |
|
|
............................................................................................................................................................................... |
 |
Transducer (Din
Rail) |
- Input : Ac Amp., AC volts, Frequency, Resistance, watt.
- Output : 4-20 mADC Linear.
- Supply : 230/110 VAC.
- Accuracy : ± 0.2% of span.
- Load resistance : 0-750 ohms.
- Loop power consumption.
|
DIN RAIL |
|
Catalogue |
|
|
............................................................................................................................................................................... |
 |
KVA Transducer |
- Input voltage (415/230/110VAC) Input Current.(0-1/0-5 Amp).
- Output : 4-20 mADC Linear, 1.5V DC Linear.
- Supply : 230/110 VAC.
- Accuracy : ± 0.2% of span.
- Load resistance : 0-750 ohms.
- Loop power consumption.
|
|
|
|
|
|
............................................................................................................................................................................... |
 |
Power Factor Transducer |
|
150(W)x70(H)x112(D)mm |
- Input voltage from PT & current from CT.
- 3 phase type.
- Supply : 230/110V AC.
- Mounting : Dinrail
- Optical & galvanic isolation.
- Load resistance : 0-750 ohms.
- Loop power consumption.
|
PFT |
|
|
|
|
............................................................................................................................................................................... |
 |
Dual/ Quad output Transducer |
- Input voltage. (415/230/110V AC) input current. (0-1/0-5 Amp)
- Connection 3ø-3w/3ø-4w/single ø.
- Output : 4-20 mADC,1-5V DC linear.
- Galvanic isolation.
|
TRANS D/Q |
|
|
|
|
............................................................................................................................................................................... |
|
KW Indicator |
|
96(W)x96(H)x173(D)mm |
- Input : CT & PT.
- Connection 3ø-3w/3ø-4w/Single ø.
- Power factor 0.5 Lag-Unity-0.5 Lead.
- Display 7 segment , 3½ digit, 0.56” height.
- Flush panel mounting.
|
KWI-01 |
|
|
|
|
............................................................................................................................................................................... |
|
Power Factor Correction Relay. |
|
144(H)x144(W)x200(D)mm |
- PF setting digitally from 0.1 to 0.99.
- 8/16 nos. of relay change over contacts.
- LED indication for over voltage, time delay, lead, lag, error & healthy working.
- Input supply : 415V AC.
|
|
|
|
|
|
............................................................................................................................................................................... |
 |
Power Factor Indicator |
|
96(W)x96(H)x173(D)mm |
- Type 3 phase 4 wire.
- Input voltage : 415/230/110V AC. input current : 1/5 Amp.
- Power factor : 0.5 Lag-Unity-0.5 Lead.
- Display : 7 segment, 3 digit, 0.56” height.
|
PF-202 |
|
|
|
|
............................................................................................................................................................................... |
 |
AC Amp to Freq. Transducer AC Volt to Freq. Transducer |
|
75(W)x70(H)x112(D)mm
|
- Input :AC Amp/AC Volts
- Output : 1-5/1-10 KHz.
- Supply : 230/110V AC.
- Load resistance : 0-500 Ohms.
- Application : It saves analog channels in PLC.
|
TRANS-F |
|
|
|
|
...............................................................................................................................................................................
|
 |
Kilo Watt Hr. Trans. |
|
222(W)x146(H)x55(D)mm
|
- Input : voltage from PT & current from CT.
- Output ranges : 0-3000 Pulses/Hr.
- Optically isolated pulse output (24V DC/110 /230V AC).
- Linear isolated o/p 4-20 mA corresponding to energy consumed.
|
µKwh |
|
|
|
|
...............................................................................................................................................................................
|
 |
Tap Position Trans. |
100(W)x70(H)x112(D)mm |
- Input : 4 ranges,50 - 1kΩ, 1kW -5kΩ, 5kΩ - 8kΩ, 8kΩ - 40kΩ. i.e. tunable at site with 25 steps.
- Output 1 : 4-20 mA (for RTU).
- Output 2 : 4-20 mA (corresponding to tap position.)
- Supply : 48V DC.
|
| TRANS-TAP-100 |
|
|
|
|
|
...............................................................................................................................................................................
 |
DC Voltage to RS485 Converter Tap Position to RS485 Converter |
- Input : 0-40 kΏ/0-10 VDC.
- Output : RS 485 (Modbus).
- Calibration through software.
- Supply : 230V AC.
|
|
|
DataSheet |
|
............................................................................................................................................................................... |
 |
Mega Watt Indicator |
530(W)x196(H)x100(D)mm |
- Input : CT & PT.
- Connection : 3ø-3w/3ø-4w.
- Input voltage : 415/230/110V AC, input current : 1/5 Amp.
- Display : 7 segment , 3½/4½ digit, 4” height.
- Galvanic isolation.
|
MW-101 |
|
|
|
............................................................................................................................................................................. |
| |
................................................................................................................................................................................
|