| Pyrotech Electronics Pvt. Ltd. (Unit - I) |
 |
SEQUENCE TIMER (MICRO CONTROLLER BASED) |
| MODEL CODES |
| Model |
µST –19 |
| Type |
Relay output. |
|
|
| INPUT/OUTPUT |
| Input |
Sequence cycle ON contact. |
Output |
One relay c/o contact for each channel. |
Contact rating |
6A at 230VAC. |
|
|
| DISPLAY |
Display |
(A) Set time/balance time on 7 segment display.
(B) Channel on/off/bypass indication by LED. |
Size of digit |
0.5”(12.5mm). |
BI colour LEDs |
Separate bi colour LED for on/off/ch. Bypass indication.
(A) On duration – Green
(B) Off duration – Red
(C) Ch.bypass – Yellow |
Red colour LEDs |
5mm size for prg/run mode, unit(hr.,min.,sec.,msec.),
On, off, cycle time status indication. |
|
|
| MODE OF OPERATION |
| On duration units |
msec./sec./min.selectable through front key common For all channel. |
Off duration |
Sec./min. selectable through front key common for All channel. |
Cycle time (at end of Each cycle) unit |
Min./hr. selectable through front key. |
Cycle time duration |
settable by key. |
Max. no. of channels |
48 |
On duration |
Settable individually for each channel. |
Off duration |
Settable individually for each channel. |
Channel bypass |
Settable individually for each channel. |
| GENERAL SPECIFICATION |
Accuracy
(A) Sec. delays
(B) Min. delays
(C) Hr. delay |
±0.5% of range
±0.5% of range
±0.5% of range |
No. of channel |
1-24 nos. factory set. |
Max. no.of operational |
Settable through front key. |
Ch. Ranges.
(A) On time duration
(B) Off time duration
(C) Cycle time duration |
1-999 msec. or 1-999 sec. or 1-9 min.
1-999 sec. or 1-99 min.
1-999 min. or 0-9 hrs.
(Other ranges are available on request.) |
| INSTALLATION |
Power supply |
(A) 110 VAC±10% , 50Hz
(B) 230 VAC±10% ,50Hz |
Operating Ambient |
-Temperature |
0-55 °C |
-Humidity |
5 –95 % RH.(Non condensing). |
Storage temp. |
0 to 60°C |
Mounting |
Field Mounted . |
Housing |
High impact ABS |
Terminals |
Suitable for conductors upto 1.5mmsq. wire only. |
| Protection Class |
IP-55 . |
Cable entry |
4/6 cable gland size ½”. |
|
|
| SPECIAL FEATURES |
 |
Optical isolation between input & output. |
 |
“Bypass” message flash on 7 Segment when all channels are bypass. |
 |
“RLY OPEN” flashing indication after current channel if initiated contact opens. |
 |
Err/data err message is displayed for a short while if the data selected through the front key does not suit as per unit selected or vice versa. |
 |
New data selected through front key are implemented at the beginning of new cycle or if reset key pressed. |
 |
Reset key provided if user wants the cycle to restart from beginning. |
 |
Key lock provision to avoid programmed data tempering. |
 |
On power OFF , on/off status , balance time left and channel number are saved. |
 |
During run mode , run mode LED flashes to indicate healthy functioning of system. |
 |
A set of seven keys , six for programming and one for resetting function . |
 |
If the system is in pause time period during power off state then at power on system sequence starts from the beginning. |
|
|
 |