| INPUT/OUTPUT |
| Input |
Sequence cycle ON contact. |
| Output |
One relay c/o contact for each channel. |
| Contact rating |
6A at 230VAC. |
|
|
| DISPLAY |
| Display |
(A) Channel no./Set time/Balance time on 7 segment display.
(B) Channel on/off/bypass indication by LED. |
| Size of digit |
0.5”. |
| BI colour LEDs |
Separate bi colour LED for on/off/bypass channel indication.
(A) On duration – Green
(B) Off duration – Red
(C) Ch.bypass – Yellow |
| Red colour LEDs |
5 mm size for prg/run mode, unit(hr., min., sec., msec.), on, off, pause time status indication. |
|
|
| MODE OF OPERATION |
| On duration units |
msec/sec/min selectable through front key common for all channel. |
| Off duration |
Sec./min. selectable through front key common for All channel. |
| Pause time(at end of each cycle) unit |
Min/hr.selectable thru front key. |
| Pause time duration max. no. of channels |
24 |
| On duration |
Settable individually for each channel. |
| Off duration |
Settable individually for each channel. |
| Channel bypass |
Settable individually for each channel. |
|
|
| GENERAL SPECIFICATION |
Accuracy
(A) Sec. delays
(B) Min. delays
(C) Hr. delay |
±0.5% of range
±0.5% of range
±0.5% of range |
| No. of channel |
1-24 nos. factory set. |
| Max. no.of operational ch. Ranges |
Settable through front key. |
(A) On time duration
(B) Off time duration
(C) Pause time duration |
1-999 msec. or 1-999 sec. or 1-9 min.
1-999 sec. or 1-99 min.
0-999 min. or 0-9 hrs.
|
|
|
| INSTALLATION |
| Power supply |
90-270 VAC, 50Hz |
| Power Fuse |
2 A. |
| Operating Ambient |
| -Temperature |
0-55°C |
| -Humidity |
5 –95 % RH.(Non condensing). |
| Storage temp. |
0° - 60°C |
| Mounting |
Field mounted. |
| Housing |
High impact ABS. |
| Terminals |
Suitable for conductors upto 1.5mmsq. wire only. |
| Protection Class |
Suitable for conductors upto 1.5 Sq. mm wire only. |
| Cable entry |
4/6 cable gland size 1/2”. |
| Size |
266(W) X186(L)X96(D) in mm. |
|
|
| SPECIAL FEATURES :- |
 |
Optical isolation between input and output. |
 |
“ALL BPAS” message flash on seven segment when all channels are bypass. |
 |
“OPEN” flashing indication after current channel if initiation contact opens. |
 |
New data selected through front key are implemented in the channel next to the channel on display or if reset key (up & down key pressed simultaneously ) pressed. |
 |
Reset (up & down key pressed simultaneously) key provided if user wants the cycle to restart from beginning. |
 |
Key lock provision to avoid programmed data tampering. |
 |
On power off, on/off status, balance time left and channel number are saved |
 |
During run mode, run mode LED flashes to indicate healthy functioning of system. |
 |
A set of three keys (mode, up and down) provided for programming and resetting function. |
 |
If the system is in pause time period during power off state then at power on system sequence starts from beginning. |
|