| Pyrotech Electronics Pvt. Ltd. (Unit - I) |
 |
ISOLATION AMPLIFIER |
| MODEL CODES |
| Model |
ISO-5 |
| Type |
4-Wire transmitter |
|
|
| INPUT/OUPUT |
| Input A |
mV, Volt, mA. |
Range
|
0-3.3 mV, 0-10 V
0-50mV, 0-100 V
0-100 mV, 0-1 mA
0-250 mV, 0-5 mA
0-500mV , 0-10 mA
0-1V, 0-20 mA
0-5 V, 4-20 mA
(Selectable any one thru. Dip switch) |
Input B |
RTD
0-400 °C |
Input impedance for circuit |
50 W for current.
10 M Ω for voltage.
|
Output |
0-20 mA, 20-0 mA
4-20 mA, 20-0 mA
0-10 V. |
Output Ripple |
Better than ± 0.25 % r.m.s. |
Load on Output |
0-600 W. |
|
|
| GENERAL SPECIFICATIONS |
Isolation |
Optical & Galvanic isolation of 1.0 KV is provided between input & output. |
Adjustment |
Zero and span are adjustable by two individual trimpots. |
Burn out protection |
Down scale for input A
Up scale for input B |
Anti-humidity treatment |
Acryform conformal coating on PCB. |
Housing Material |
ABS |
Power fuse |
0.25 (for externally powered} |
| |
|
| MODEL CODES |
Wiring |
Screw terminals (M 3) |
Linearity |
Within ± 0.5% of span. |
Accuracy |
±0.5% or better. |
Response Time |
Within 1 second. |
Line voltage variation effect |
± 0.1% (within ± 10% change). |
Insulation strength |
Tested at 1.0 KV for all possible combination for 1 Min. and at 500 VAC between electronics & earth. |
|
|
| INSTALLATION |
Power supply |
24 VDC ±10%
110/230 VAC±10% (Only in Din rail version) |
Supply Current |
Maximum 65 mA (for single O/P) |
Operating Ambient |
|
-Temperature |
0-60 °C |
Mounting |
DIN Rail 35 mm standard/Field mounted. |
Housing |
ABS |
Terminal |
M3 suitable for conductors upto 2.5 sq. mm. |
Size (DIN RAIL)
(ABS) |
70 (H) x 60 (W) x 115 (D) in mm
171 (H) x 121 (W) x 55 (D) in mm |
| Weight |
Approximately 400 gms. |
| *DUAL OUTPUTS IS AVAILABLE (ON REQUEST) |
|
 |